Veterinary Vital Signs Monitor
SpotLife® Veterinary is a vital signs monitor that comes in 3 versions for the benefit of the veterinary market. The SpO2-Only model helps accurate oximetry monitoring of even the smallest animals thanks to its high performances in low perfusion condition. The 2 other models include capnography (mainstream or sidestream) along with oximetry. They will appear to be indispensable and reliable for intubated animals during surgery.
The clear and easy-to-read LCD will show real-time pleth and capnogram, allowing vets to confirm proper intubation, and whether the animal is in respiratory distress. SpotLife compatible airway adapters allow a smooth connection to any anesthesia systems.
Its handle and light weight make it easy for transport use as well as use in operating theaters. Cost effective, it remains a comprehensive device for multiple applications on a wide range of animals and environments.
All models are based on our SpO2 module and provide the same high performance, while our CO2 models will be using either our CO2 mainstream or external sidestream modules.
SPECIFICATIONS
-
Functions
-
Oximetry (all models)
-
Real-time measurement of SpO2, pulse rate (PR), perfusion index (PI), and Variability of Pulse Index (PIV).
-
Real-time photoplethysmogram display
-
High accuracy and reliability even with low blood perfusion down to 0.05%, allowing application on small animals.
-
Capnography (SPLFV-SE and SPLFV-MC models)
-
Measurement of EtCO2, FiCO2 and Respiratory Rate (awRR)
-
Real-time capnogram display
-
Automatic barometric pressure, temperature compensation and manual anaesthetic gases compensation
-
Fixed Micro Flow: 50 ml/min (±10ml/min) (SPLFV-SE Model only)
-
Thermometry (Option TBD):
-
Body temperature measurement using Fast temperature probe
-
Environmental characteristics
-
Operating Conditions
-
Temperature: 0°C ~ 40°C
-
Humidity: 15 ~ 95%, non-condensation
-
Atmospheric pressure: 70.0kPa ~ 106.0kPa
-
Storage Conditions
-
Temperature: -20 ~ 70°C (4 to 158°F)
-
Humidity: 15 ~ 95%, non-condensation
-
Atmospheric pressure: 57.3kPa ~ 106.0kPa
-
Electrical and Mechanical characteristics
-
Electrical Power Supply
-
AC: 100 ~ 240V ± 10% (built-in adapter)
-
Input power: 60VA
-
Frequency: 50Hz/60Hz ± 3Hz
-
One equipotential grounding interface
-
Product Class: IIb (in accordance with MDD93 /42/ EEC)
-
Battery
-
Built-in rechargeable lithium batteries: 11.1 V / 2400mAh
-
Mechanical
-
Dimensions: 255 x 140 x 95mm (LxWxH)
-
Weight: < 2kg (without accessories)
-
Interfaces
-
Connectivity
-
USB interface
-
RS232 DB9 interface
-
HMI
-
Five buttons: Power switch, alarm stop, alarm pause, up and down buttons, menu
-
Display: 5” Color TFT LCD, 800 x 480pixels
-
Audio/Visual Indicators: Alarm limit reached, Alarm tone, Alarm mute, pulse strength, Patient name, Patient Type, Time, battery status, connection status.
-
LEDs: Adult, Neonate, SpO2/PR (according to model), battery in use, battery charging, silenced alarm.
-
User Interface language: English, French, Italian, Hungarian (additional language upon request).
-
Performances
-
SpO2 (all models)
-
Sp02: Measurement Range: 0 – 100%; Accuracy Range: from 70 – 100 % = ±2%, below 70%, Undefined; Resolution: 1%
-
Pulse Rate: Measurement Range: 25-250 BPM; Accuracy Range: ±2%; Resolution: 1 bpm
-
PI: Measurement Range: 0-20%; Resolution: 0.001%
-
PIV: Measurement Range: 0-100%; Accuracy Range: Undefined; Resolution: 1%
-
Capnography (SPLFV-MC and SPLFV-SE models)
-
Method: Infrared radiation absorption technology
-
CO2 measurement range: 0 ~ 20 %
-
Accuracy: – 0 ~ 12% : ±(0.2 Vol% + 2% of reading), – 12 ~ 20% : ±(0.2 Vol% + 6% of reading)
-
Measurement accuracy drift: accuracy requirements within 6 hours
-
Resolution: 0.1 Vol%
-
Accuracy: Mean error: < ±5mmHg, Standard deviation: < 8mmHg
-
Apnea alarm delay time: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
-
Alarm range: – EtCO2: 0 ~ 150mmHg, – FiCO2: 0 ~ 150mmHg, – AwRR: 0 ~ 150rpm
-
Features
-
Bright, large 5” Color TFT LCD for better readability of all parameters.
-
Intuitive user interface.
-
3 models availables:
-
• SpO2 only (Model #SPLFV-OX)
• SpO2 + Mainstream CO2 (Model #SPLFV-MC)
• SpO2 + Sidestream CO2 (Model #SPLFV-SE)
-
Selectable Display Modes:
-
• digits only, showing parameters values
• digits and graphs, showing real-time plethysmogram and capnogram (according to model)
• digits, graph, and trends, displaying, in addition, the historical values.
-
9 LED indicators to easily control patient type, units, power and alarm status.
-
New patient presets allowing a one-step action to set all alarms limits according to patient type (Adult, Child, Neonate).
-
360° Visible and Audible alarms.
-
Over 72h trend data with a 1 min resolution.
-
Built-in power supply and 2400mAh lithium battery for 6h continuous monitoring.
-
Extension port upon request for custom protocols, raw data output for research and other device connectivity.
-
USB port for easy updates with new software functions (further connectivity and control options, addition of peripherals).
-
Ordering Information
-
Model #SPLFV-OX : SpotLife® Oximeter Only, with reusable animal tongue/ear clip SpO2 probe
-
Model #SPLFV-MC : SpotLife® Oximeter and Mainstream CO2 sensor, with reusable animal tongue/ear clip SpO2 probe, one set of disposable small and big airway adapters for small and large animal applications
-
Model #SPLFV-SE : SpotLife® Oximeter and External Sidestream CO2 sensor, with reusable animal tongue/ear clip SpO2 probe, CO2 microstream sampling line.
-
Downloads